English getting-started guide · 1.1.3
Your first steps in JDesignCAD.
Install the application, switch to English, choose drawing units, and explore the IFC-to-Revit workflow.
1. Install and launch.
- Download the official EXE from the English download page.
- If replacing an existing installation, save your drawings and close JDesignCAD first. Keep backups of important JDC files.
- Run setup, review the license agreement, and select the installation folder. Administrator permission is required.
- Allow setup to install missing runtimes, then launch JDesignCAD.
The Free edition supports commercial use. A paid subscription is a separate purchase.
Download and system requirements2. Switch to English.
- Open the application-wide settings. In Japanese, look for 「全体設定」.
- Find 「言語」 (language) and select English / 「英語」. Confirm the setting.
- Save any open drawings.
- Close and restart JDesignCAD. The language changes after restarting.
To return to Japanese, choose Japanese / 「日本語」 and restart again.
Language and drawing units are separate settings. Choosing English does not switch your drawing to inches. Existing drawing names, component names, and user-entered text are not automatically translated.
3. Choose model units.
In Property Explorer, open the project settings and choose the units for the target model: millimeters, centimeters, meters, kilometers, inches, or feet.
A line that is 25.4 mm long displays as 1 inch. Switching display units does not scale existing geometry. Model coordinates are stored internally in millimeters, with conversions for input and display.
Some fields keep their own units
Paper, layout, dimension text and arrow settings, and certain application defaults remain in millimeters. Follow any mm, px, or other unit labels shown in a field. Hole, analysis, and IFC dialogs retain their explicitly labeled units. This release does not switch analysis inputs to inch/lbf/psi.
Importing geometry
DWG/DXF, STEP, and SAT use file unit information. STL and OBJ normally have no unit metadata: set the file length unit in the application-wide STL / OBJ import settings before opening them. The default is millimeters. STL/OBJ export uses millimeters.
Imported blocks preserve their base units and are converted during placement. Do not manually multiply an inch-based component by 25.4 merely to place it in a millimeter drawing.
4. Understand your license.
Start with Free for core drafting and modeling. Features that require Standard include the supported external-format exports, IFC export, CAE, and creating or editing 3D dynamic block face actions.
For a paid subscription, follow the instructions supplied with your purchase. The English License Management dialog shows the current plan and expiry date and provides Activate license and Return license controls. Activation requires internet access.
Keep application keys and other licensing details private. Mask them in screenshots and support materials shared publicly. Detailed purchase and activation instructions for international customers must be confirmed before launch.
5. Create your first drawing.
- Start a new drawing and check its model units.
- Begin with a line, rectangle, or circle on the XY work plane. Use object snaps and tracking to position geometry.
- For 3D, create a closed profile and extrude it. Adjust the work plane to draw on another face or orientation.
- Save in JDC to keep JDesignCAD editing information. Keep this original before exporting to another format.
- Use layouts to arrange views for printing. Check paper settings and scale separately from model units.
This is an introductory guide, not the complete command reference.
Open the full reference · Browse video tutorials (Japanese audio)6. Export IFC and create a Revit family.
Export the component in JDesignCAD
- With Standard or above, use the IFC library export command under the Insert ribbon’s export tools. The Japanese command is 「IFCライブラリ書き出し」.
- Select the component’s 3D geometry. Set its classification, name, manufacturer, model number, and standard properties. Use additional product specifications for other name/value pairs.
- If required, configure supported IN/OUT ports. Verify position, outward direction, dimensions, and units before export.
- Choose IFC2x3 or IFC4. Use IFC4 for curved BRep output. Save the IFC file.
Prepare Dynamo Player in Revit
- Download and extract the converter ZIP, or copy the files from the installation folder’s
Revit/Dynamodirectory into a convenient user folder. - Use Revit 2026 or 2027 with its bundled Dynamo / Dynamo Player and metric family templates. Revit LT and standalone Dynamo are not supported.
- Open a project in Revit. An empty project is sufficient.
- Open Manage → Dynamo Player and select the folder containing the supplied .dyn files. If asked to trust a file, verify its source first.
- Run
JDesignCAD_IFCからファミリ_Revit2026.dynfor Revit 2026 (CPython3), orJDesignCAD_IFCからファミリ_Revit2027.dynfor Revit 2027 (PythonNet3). - Select the IFC exported by JDesignCAD and choose an RFA file name and save location. No IFC linking, binding, or ungrouping is required.
- If a template cannot be found automatically, choose an unhosted metric Generic Model or Furniture .rft template. Do not use a template with existing geometry or wall/ceiling hosts.
- After completion, open the RFA or load it into the project. Inspect geometry, family parameters, and any connectors before use.
No additional product add-in or Dynamo package is required. Use the file matching your Revit year.
Know the limits
The result is a fixed-geometry loadable family. Changing a reference dimension does not stretch the shape. A 2027 RFA cannot be opened in 2026; create in 2026 when you need to distribute to both versions.
The converter handles a single component exported by JDesignCAD, not arbitrary IFC buildings. Unsupported categories may become Generic Model families, retaining the IFC classification as properties. It does not create hosted door/window cutouts, light sources, structural analytical models, or rendering textures.
Connection ports
Supported ports must lie on identifiable planar end faces. Curved-face points or ports away from an end face are not supported. Circular piping uses PIPE / CIRCULAR with nominal diameter in mm; SINK means IN, SOURCE means OUT, and SOURCEANDSINK means bidirectional.
Electrical input uses CABLE / ELECTRICAL / SINK and requires voltage, pole count, and apparent power specifications. Electrical output, control/communication, duct, and conduit connectors are outside this version’s scope. Follow the exact specification names in the supplied converter instructions.
Changing a linked connector parameter changes the connector, not the fixed model’s hole diameter or outline. Connect piping or create an electrical circuit in the project after loading.
See the full English reference manual for detailed connector setup and command instructions. Check those conditions before converting equipment.
Download converter7. Checks before asking for help.
- Still in Japanese? Check that you are running 1.0.7 or later, confirm the language selection, save your work, and restart.
- Wrong model size? Check source file units, especially for STL/OBJ. Changing display units is not a scaling operation.
- Export unavailable? Check the required edition and active license.
- Dynamo conversion fails? Confirm the Revit year, matching .dyn file, and metric templates. Record the detailed error and the source IFC. The converter stops on unsupported or failed transfers rather than silently omitting geometry.
- Security warning? Verify the source and valid publisher signature. Do not disable security controls to proceed.
For support, retain the application version, steps to reproduce, exact error, and a non-confidential sample if possible. Mask license keys. Current support is through community posts for Standard-or-higher users; please check with the provider about English-language support availability.
Extend your workflow: sheet metal, API and MCP.
The core 2D and 3D tools remain available. When you are ready, use the new guides below. Review the license conditions before starting.
MCP connections are available in Free. Operations remain subject to your CAD license. Check your AI provider’s separate terms and fees. Free runs the bundled API samples only. Custom DLLs and modified samples require STD or above. Pro remains in development.